Skip to content

Commit

Permalink
errors, child_process: migrate to using internal/errors
Browse files Browse the repository at this point in the history
PR-URL: nodejs#11300
Ref: nodejs#11273
Reviewed-By: Michaël Zasso <[email protected]>
Reviewed-By: Michael Dawson <[email protected]>
  • Loading branch information
jasnell committed Apr 27, 2017
1 parent f0b7025 commit 7632761
Show file tree
Hide file tree
Showing 10 changed files with 111 additions and 33 deletions.
61 changes: 61 additions & 0 deletions doc/api/errors.md
Original file line number Diff line number Diff line change
Expand Up @@ -599,6 +599,27 @@ Node.js API that consumes `file:` URLs (such as certain functions in the
[`fs`][] module) encounters a file URL with an incompatible path. The exact
semantics for determining whether a path can be used is platform-dependent.

<a id="ERR_INVALID_HANDLE_TYPE"></a>
### ERR_INVALID_HANDLE_TYPE

The '`ERR_INVALID_HANDLE_TYPE`' error code is used when an attempt is made to
send an unsupported "handle" over an IPC communication channel to a child
process. See [`child.send()`] and [`process.send()`] for more information.

<a id="ERR_INVALID_OPT_VALUE"></a>
### ERR_INVALID_OPT_VALUE

The `'ERR_INVALID_OPT_VALUE'` error code is used generically to identify when
an invalid or unexpected value has been passed in an options object.

<a id="ERR_INVALID_SYNC_FORK_INPUT"></a>
### ERR_INVALID_SYNC_FORK_INPUT

The `'ERR_INVALID_SYNC_FORK_INPUT'` error code is used when a `Buffer`,
`Uint8Array` or `string` is provided as stdio input to a synchronous
fork. See the documentation for the [`child_process`](child_process.html)
module for more information.

<a id="ERR_INVALID_THIS"></a>
### ERR_INVALID_THIS

Expand Down Expand Up @@ -642,6 +663,36 @@ It is currently only used in the [WHATWG URL API][] support in the [`fs`][]
module (which only accepts URLs with `'file'` scheme), but may be used in other
Node.js APIs as well in the future.

<a id="ERR_IPC_CHANNEL_CLOSED"></a>
### ERR_IPC_CHANNEL_CLOSED

The `'ERR_IPC_CHANNEL_CLOSED'` error code is used when an attempt is made to use
an IPC communication channel that has already been closed.

<a id="ERR_IPC_DISCONNECTED"></a>
### ERR_IPC_DISCONNECTED

The `'ERR_IPC_DISCONNECTED'` error code is used when an attempt is made to
disconnect an already disconnected IPC communication channel between two
Node.js processes. See the documentation for the
[`child_process`](child_process.html) module for more information.

<a id="ERR_IPC_ONE_PIPE"></a>
### ERR_IPC_ONE_PIPE

The `'ERR_IPC_ONE_PIPE'` error code is used when an attempt is made to create
a child Node.js process using more than one IPC communication channel.
See the documentation for the [`child_process`](child_process.html)
module for more information.

<a id="ERR_IPC_SYNC_FORK"></a>
### ERR_IPC_SYNC_FORK

The `'ERR_IPC_SYNC_FORK'` error code is used when an attempt is made to open
an IPC communication channel with a synchronous forked Node.js process.
See the documentation for the [`child_process`](child_process.html)
module for more information.

<a id="ERR_MISSING_ARGS"></a>
### ERR_MISSING_ARGS

Expand Down Expand Up @@ -674,6 +725,13 @@ kind of internal Node.js error that should not typically be triggered by user
code. Instances of this error point to an internal bug within the Node.js
binary itself.

<a id="ERR_UNKNOWN_SIGNAL"></a>
### ERR_UNKNOWN_SIGNAL

The `'ERR_UNKNOWN_SIGNAL`' error code is used when an invalid or unknown
process signal is passed to an API expecting a valid signal (such as
[`child.kill()`][]).

<a id="ERR_UNKNOWN_STDIN_TYPE"></a>
### ERR_UNKNOWN_STDIN_TYPE

Expand All @@ -693,6 +751,9 @@ in user code, although it is not impossible. Occurrences of this error are most
likely an indication of a bug within Node.js itself.


[`child.kill()`]: child_process.html#child_process_child_kill_signal
[`child.send()`]: child_process.html#child_process_child_send_message_sendhandle_options_callback
[`process.send()`]: process.html#process_process_send_message_sendhandle_options_callback
[`fs.readdir`]: fs.html#fs_fs_readdir_path_options_callback
[`fs.readFileSync`]: fs.html#fs_fs_readfilesync_file_options
[`fs.unlink`]: fs.html#fs_fs_unlink_path_callback
Expand Down
32 changes: 17 additions & 15 deletions lib/internal/child_process.js
Original file line number Diff line number Diff line change
@@ -1,5 +1,6 @@
'use strict';

const errors = require('internal/errors');
const StringDecoder = require('string_decoder').StringDecoder;
const EventEmitter = require('events');
const net = require('net');
Expand Down Expand Up @@ -367,6 +368,7 @@ function onErrorNT(self, err) {


ChildProcess.prototype.kill = function(sig) {

const signal = sig === 0 ? sig :
convertToValidSignal(sig === undefined ? 'SIGTERM' : sig);

Expand Down Expand Up @@ -538,15 +540,15 @@ function setupChannel(target, channel) {
options = undefined;
} else if (options !== undefined &&
(options === null || typeof options !== 'object')) {
throw new TypeError('"options" argument must be an object');
throw new errors.TypeError('ERR_INVALID_ARG_TYPE', 'options', 'Object');
}

options = Object.assign({swallowErrors: false}, options);

if (this.connected) {
return this._send(message, handle, options, callback);
}
const ex = new Error('channel closed');
const ex = new errors.Error('ERR_IPC_CHANNEL_CLOSED');
if (typeof callback === 'function') {
process.nextTick(callback, ex);
} else {
Expand All @@ -559,7 +561,7 @@ function setupChannel(target, channel) {
assert(this.connected || this.channel);

if (message === undefined)
throw new TypeError('"message" argument cannot be undefined');
throw new errors.TypeError('ERR_MISSING_ARGS', 'message');

// Support legacy function signature
if (typeof options === 'boolean') {
Expand All @@ -586,7 +588,7 @@ function setupChannel(target, channel) {
} else if (handle instanceof UDP) {
message.type = 'dgram.Native';
} else {
throw new TypeError('This handle type can\'t be sent');
throw new errors.TypeError('ERR_INVALID_HANDLE_TYPE');
}

// Queue-up message and handle if we haven't received ACK yet.
Expand Down Expand Up @@ -686,7 +688,7 @@ function setupChannel(target, channel) {

target.disconnect = function() {
if (!this.connected) {
this.emit('error', new Error('IPC channel is already disconnected'));
this.emit('error', new errors.Error('ERR_IPC_DISCONNECTED'));
return;
}

Expand Down Expand Up @@ -766,11 +768,12 @@ function _validateStdio(stdio, sync) {
case 'ignore': stdio = ['ignore', 'ignore', 'ignore']; break;
case 'pipe': stdio = ['pipe', 'pipe', 'pipe']; break;
case 'inherit': stdio = [0, 1, 2]; break;
default: throw new TypeError('Incorrect value of stdio option: ' + stdio);
default:
throw new errors.TypeError('ERR_INVALID_OPT_VALUE', 'stdio', stdio);
}
} else if (!Array.isArray(stdio)) {
throw new TypeError('Incorrect value of stdio option: ' +
util.inspect(stdio));
throw new errors.TypeError('ERR_INVALID_OPT_VALUE',
'stdio', util.inspect(stdio));
}

// At least 3 stdio will be created
Expand Down Expand Up @@ -812,9 +815,9 @@ function _validateStdio(stdio, sync) {
// Cleanup previously created pipes
cleanup();
if (!sync)
throw new Error('Child process can have only one IPC pipe');
throw new errors.Error('ERR_IPC_ONE_PIPE');
else
throw new Error('You cannot use IPC with synchronous forks');
throw new errors.Error('ERR_IPC_SYNC_FORK');
}

ipc = new Pipe(true);
Expand Down Expand Up @@ -849,15 +852,14 @@ function _validateStdio(stdio, sync) {
} else if (isUint8Array(stdio) || typeof stdio === 'string') {
if (!sync) {
cleanup();
throw new TypeError('Asynchronous forks do not support ' +
'Buffer, Uint8Array or string input: ' +
util.inspect(stdio));
throw new errors.TypeError('ERR_INVALID_SYNC_FORK_INPUT',
util.inspect(stdio));
}
} else {
// Cleanup
cleanup();
throw new TypeError('Incorrect value for stdio stream: ' +
util.inspect(stdio));
throw new errors.TypeError('ERR_INVALID_OPT_VALUE', 'stdio',
util.inspect(stdio));
}

return acc;
Expand Down
17 changes: 16 additions & 1 deletion lib/internal/errors.js
Original file line number Diff line number Diff line change
Expand Up @@ -91,17 +91,32 @@ E('ERR_INVALID_ARG_TYPE', invalidArgType);
E('ERR_INVALID_CALLBACK', 'callback must be a function');
E('ERR_INVALID_FILE_URL_HOST', 'File URL host %s');
E('ERR_INVALID_FILE_URL_PATH', 'File URL path %s');
E('ERR_INVALID_HANDLE_TYPE', 'This handle type cannot be sent');
E('ERR_INVALID_OPT_VALUE',
(name, value) => {
return `The value "${String(value)}" is invalid for option "${name}"`;
});
E('ERR_INVALID_SYNC_FORK_INPUT',
(value) => {
return 'Asynchronous forks do not support Buffer, Uint8Array or string' +
`input: ${value}`;
});
E('ERR_INVALID_THIS', 'Value of "this" must be of type %s');
E('ERR_INVALID_TUPLE', '%s must be an iterable %s tuple');
E('ERR_INVALID_URL', 'Invalid URL: %s');
E('ERR_INVALID_URL_SCHEME',
(expected) => `The URL must be ${oneOf(expected, 'scheme')}`);
E('ERR_IPC_CHANNEL_CLOSED', 'channel closed');
E('ERR_IPC_DISCONNECTED', 'IPC channel is already disconnected');
E('ERR_IPC_ONE_PIPE', 'Child process can have only one IPC pipe');
E('ERR_IPC_SYNC_FORK', 'IPC cannot be used with synchronous forks');
E('ERR_MISSING_ARGS', missingArgs);
E('ERR_STDERR_CLOSE', 'process.stderr cannot be closed');
E('ERR_STDOUT_CLOSE', 'process.stdout cannot be closed');
E('ERR_UNKNOWN_BUILTIN_MODULE', (id) => `No such built-in module: ${id}`);
E('ERR_UNKNOWN_SIGNAL', (signal) => `Unknown signal: ${signal}`);
E('ERR_UNKNOWN_STDIN_TYPE', 'Unknown stdin file type');
E('ERR_UNKNOWN_STREAM_TYPE', 'Unknown stream file type');
E('ERR_UNKNOWN_BUILTIN_MODULE', (id) => `No such built-in module: ${id}`);
// Add new errors from here...

function invalidArgType(name, expected, actual) {
Expand Down
3 changes: 2 additions & 1 deletion lib/internal/util.js
Original file line number Diff line number Diff line change
@@ -1,5 +1,6 @@
'use strict';

const errors = require('internal/errors');
const binding = process.binding('util');
const signals = process.binding('constants').os.signals;

Expand Down Expand Up @@ -177,7 +178,7 @@ function convertToValidSignal(signal) {
if (signalName) return signalName;
}

throw new Error('Unknown signal: ' + signal);
throw new errors.Error('ERR_UNKNOWN_SIGNAL', signal);
}

function getConstructorOf(obj) {
Expand Down
4 changes: 2 additions & 2 deletions test/parallel/test-child-process-constructor.js
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
'use strict';

require('../common');
const common = require('../common');
const assert = require('assert');
const { ChildProcess } = require('child_process');
assert.strictEqual(typeof ChildProcess, 'function');
Expand Down Expand Up @@ -64,6 +64,6 @@ assert(Number.isInteger(child.pid));
// try killing with invalid signal
assert.throws(() => {
child.kill('foo');
}, /^Error: Unknown signal: foo$/);
}, common.expectsError({ code: 'ERR_UNKNOWN_SIGNAL' }));

assert.strictEqual(child.kill(), true);
2 changes: 1 addition & 1 deletion test/parallel/test-child-process-send-type-error.js
Original file line number Diff line number Diff line change
Expand Up @@ -6,7 +6,7 @@ const cp = require('child_process');
function fail(proc, args) {
assert.throws(() => {
proc.send.apply(proc, args);
}, /"options" argument must be an object/);
}, common.expectsError({code: 'ERR_INVALID_ARG_TYPE', type: TypeError}));
}

let target = process;
Expand Down
2 changes: 1 addition & 1 deletion test/parallel/test-child-process-spawnsync-kill-signal.js
Original file line number Diff line number Diff line change
Expand Up @@ -21,7 +21,7 @@ if (process.argv[2] === 'child') {
// Verify that an error is thrown for unknown signals.
assert.throws(() => {
spawn('SIG_NOT_A_REAL_SIGNAL');
}, /Error: Unknown signal: SIG_NOT_A_REAL_SIGNAL/);
}, common.expectsError({ code: 'ERR_UNKNOWN_SIGNAL' }));

// Verify that the default kill signal is SIGTERM.
{
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -185,7 +185,8 @@ if (!common.isWindows) {
{
// Validate the killSignal option
const typeErr = /^TypeError: "killSignal" must be a string or number$/;
const unknownSignalErr = /^Error: Unknown signal:/;
const unknownSignalErr =
common.expectsError({ code: 'ERR_UNKNOWN_SIGNAL' });

pass('killSignal', undefined);
pass('killSignal', null);
Expand Down
2 changes: 1 addition & 1 deletion test/parallel/test-child-process-stdio.js
Original file line number Diff line number Diff line change
Expand Up @@ -42,4 +42,4 @@ assert.deepStrictEqual(options, {stdio: 'ignore'});

assert.throws(() => {
common.spawnPwd({stdio: ['pipe', 'pipe', 'pipe', 'ipc', 'ipc']});
}, /^Error: Child process can have only one IPC pipe$/);
}, common.expectsError({code: 'ERR_IPC_ONE_PIPE', type: Error}));
18 changes: 8 additions & 10 deletions test/parallel/test-child-process-validate-stdio.js
Original file line number Diff line number Diff line change
@@ -1,19 +1,18 @@
'use strict';
// Flags: --expose_internals

require('../common');
const common = require('../common');
const assert = require('assert');
const _validateStdio = require('internal/child_process')._validateStdio;

const expectedError =
common.expectsError({code: 'ERR_INVALID_OPT_VALUE', type: TypeError});

// should throw if string and not ignore, pipe, or inherit
assert.throws(function() {
_validateStdio('foo');
}, /Incorrect value of stdio option/);
assert.throws(() => _validateStdio('foo'), expectedError);

// should throw if not a string or array
assert.throws(function() {
_validateStdio(600);
}, /Incorrect value of stdio option/);
assert.throws(() => _validateStdio(600), expectedError);

// should populate stdio with undefined if len < 3
{
Expand All @@ -27,9 +26,8 @@ assert.throws(function() {

// should throw if stdio has ipc and sync is true
const stdio2 = ['ipc', 'ipc', 'ipc'];
assert.throws(function() {
_validateStdio(stdio2, true);
}, /You cannot use IPC with synchronous forks/);
assert.throws(() => _validateStdio(stdio2, true),
common.expectsError({code: 'ERR_IPC_SYNC_FORK', type: Error}));

{
const stdio3 = [process.stdin, process.stdout, process.stderr];
Expand Down

0 comments on commit 7632761

Please sign in to comment.